Khóa điện từ AZM170-02ZRK-24VAC/DC
Thông số kỹ thuật Schmersal AZM170-02ZRK-24VAC/DC:
| Ordering details | |
Đại lý AZM170-02ZRK-24VAC/DC |
|
| Product type description | AZM 170-02ZRK 24 VAC/DC – Ordering suffix |
| Article number | 101140795 |
| EAN code | 4030661119830 |
| eCl@ss | 27-27-26-03 |
| Approval | |
| Approval | BG USA/CAN CCC |
| Classification | |
| Standards | EN ISO 13849-1 |
| B10d Opener (NC) | 2.000.000 |
| Mission time | 20 Years |
| notice | ![]() |
| Global Properties | |
| Product name | AZM 170 |
| Standards | EN 60947-5-1, BG-GS-ET-19 |
Compliance with the Directives (Y/N) ![]() |
Yes |
| Number of actuating directions | 2 piece |
| Active principle | electromechanical |
| Duty cycle | Magnet 100 % |
| Materials | |
| – Material of the housings | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| – Material of the contacts | Silver |
| Housing coating | None |
| Weight | 288 g |
| Nhà phân phối AZM170-02ZRK-24VAC/DC | |
| Mechanical data | |
| Design of electrical connection | IDC method of termination |
| Cable section | |
| – Min. Cable section | 1 x 0,75 mm² |
| – Max. Cable section | 1 x 1.0 mm², flexible |
| Mechanical life | > 1.000.000 operations |
| Emergency unlocking device (Y/N) | No |
| Manual release (Y/N) | Yes |
| – bottom | |
| Emergency release (Y/N) | No |
| Latching force | 30 N |
| Positive break force | 17 N |
| positive break travel | 11 mm |
| Clamping force F | 1000 N |
| Max. Actuating speed | 2 m/s |
| Ambient conditions | |
| Ambient temperature | |
| – Min. environmental temperature | −25 °C |
| – Max. environmental temperature | +60 °C |
| Protection class | IP67 to IEC/EN 60529 |
| Electrical data | |
| Design of control element | Opener (NC) |
| notice | change-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridges |
| Switching principle | Creep circuit element |
| Number of auxiliary contacts | 0 piece |
| Number of safety contacts | 2 piece |
| Power to unlock | Yes |
| Power to lock | No |
| Rated control voltage Us | 24 VAC/DC |
| Power consumption | max. 10 W |
| Rated impulse withstand voltage Uimp | 4 kV |
| Rated insulation voltage Ui | 250 V |
| Thermal test current Ithe | 10 A |
| Utilisation category | AC-15: 230 V / 4 A, DC-13: 24 V / 4 A |
| Max. fuse rating | 6 A gG D-fuse |
| ATEX | |
| Explosion protection categories for gases | None |
| Explosion protected category for dusts | None |
| Miscellaneous data | |
| Applications | sliding safety guard, removable guard, hinged safety guard |
| Dimensions | |
| Dimensions of the sensor | |
| – Width of sensor | 90 mm |
| – Height of sensor | 84 mm |
| – Length of sensor | 30 mm |
| notice | |
| This type termination (IDC) method enables simple connetion of flexible conductors without the need for the use of conductor ferrules | |
| Individual coding available on request | |
| Manual release | |
| • For manual release using M5 triangular key, available as accessory | |
| Diagram | |
Note Diagram |
|
| Switch travel diagram | |
Notes Switch travel diagram |
|

BG
USA/CAN
CCC

sliding safety guard,
removable guard,
hinged safety guard