Khóa điện từ AZM170-02ZRK-24VAC/DC
Thông số kỹ thuật Schmersal AZM170-02ZRK-24VAC/DC:
Ordering details | |
Đại lý AZM170-02ZRK-24VAC/DC |
|
Product type description | AZM 170-02ZRK 24 VAC/DC – Ordering suffix |
Article number | 101140795 |
EAN code | 4030661119830 |
eCl@ss | 27-27-26-03 |
Approval | |
Approval | BG USA/CAN CCC |
Classification | |
Standards | EN ISO 13849-1 |
B10d Opener (NC) | 2.000.000 |
Mission time | 20 Years |
notice | |
Global Properties | |
Product name | AZM 170 |
Standards | EN 60947-5-1, BG-GS-ET-19 |
Compliance with the Directives (Y/N) | Yes |
Number of actuating directions | 2 piece |
Active principle | electromechanical |
Duty cycle | Magnet 100 % |
Materials | |
– Material of the housings | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
– Material of the contacts | Silver |
Housing coating | None |
Weight | 288 g |
Nhà phân phối AZM170-02ZRK-24VAC/DC | |
Mechanical data | |
Design of electrical connection | IDC method of termination |
Cable section | |
– Min. Cable section | 1 x 0,75 mm² |
– Max. Cable section | 1 x 1.0 mm², flexible |
Mechanical life | > 1.000.000 operations |
Emergency unlocking device (Y/N) | No |
Manual release (Y/N) | Yes |
– bottom | |
Emergency release (Y/N) | No |
Latching force | 30 N |
Positive break force | 17 N |
positive break travel | 11 mm |
Clamping force F | 1000 N |
Max. Actuating speed | 2 m/s |
Ambient conditions | |
Ambient temperature | |
– Min. environmental temperature | −25 °C |
– Max. environmental temperature | +60 °C |
Protection class | IP67 to IEC/EN 60529 |
Electrical data | |
Design of control element | Opener (NC) |
notice | change-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridges |
Switching principle | Creep circuit element |
Number of auxiliary contacts | 0 piece |
Number of safety contacts | 2 piece |
Power to unlock | Yes |
Power to lock | No |
Rated control voltage Us | 24 VAC/DC |
Power consumption | max. 10 W |
Rated impulse withstand voltage Uimp | 4 kV |
Rated insulation voltage Ui | 250 V |
Thermal test current Ithe | 10 A |
Utilisation category | AC-15: 230 V / 4 A, DC-13: 24 V / 4 A |
Max. fuse rating | 6 A gG D-fuse |
ATEX | |
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
Miscellaneous data | |
Applications | sliding safety guard, removable guard, hinged safety guard |
Dimensions | |
Dimensions of the sensor | |
– Width of sensor | 90 mm |
– Height of sensor | 84 mm |
– Length of sensor | 30 mm |
notice | |
This type termination (IDC) method enables simple connetion of flexible conductors without the need for the use of conductor ferrules | |
Individual coding available on request | |
Manual release | |
• For manual release using M5 triangular key, available as accessory | |
Diagram | |
Note Diagram |
|
Switch travel diagram | |
Notes Switch travel diagram |