Schmersal MZM 100B ST2-1P2PW2RE-A-2781-1
Thông số kỹ thuật MZM 100B ST2-1P2PW2RE-A-2781-1
MZM 100 B ST-1P2PW2REM-A
MZM 100 B ST2-1P2PW2RE-A
MZM 100 B ST2-1P2PW2REM-A
MZM 100 B ST2-SD2PRE-A
MZM 100 B ST2-SD2PREM-A
MZM 100 ST-1P2PW-A
MZM 100 ST-1P2PWM-A
MZM 100 ST-1P2PWRE-A
MZM 100 ST-1P2PWREM-A
MZM 100 ST-SD2P-A
MZM 100 ST-SD2PRE-A
MZM 100 ST-SD2PREM-A
MZM 100 ST2-1P2PW-A
MZM 100 ST2-1P2PWM-A
MZM 100 ST2-1P2PWRE-A
MZM 100 ST2-1P2PWREM-A
MZM 100 ST2-SD2P-A
MZM 100 ST2-SD2PRE-A
MZM 100 ST2-SD2PREM-A
đại lý MZM 100B ST2-1P2PW2RE-A-2781-1 | nhà phân phối MZM 100B ST2-1P2PW2RE-A-2781-1
Ordering details | |
Product type description | MZM 100 B ST2-1P2PW2RE-A |
Article number | 101211070 |
EAN code | 4030661389080 |
eCl@ss | 27-27-26-03 |
Approval | |
Approval | BG USA/CAN |
Classification | |
Standards | EN ISO 13849-1, IEC 61508, IEC 60947-5-3, EN 60947-5-1 |
PL | e |
Control category | up 4 |
PFH | 3.5 x 10-9/h |
SIL | up 3 |
Mission time | 20 Years |
Classification | PDF-M |
Global Properties | |
Product name | MZM 100 |
Standards | IEC 61508, EN ISO 13849-1, EN ISO 13849-1 |
Compliance with the Directives (Y/N) | Yes |
Suitable for safety functions (Y/N) | Yes |
Protection rating | II |
Series-wiring | up to 31 components |
Length of the sensor chain | max. 200 m |
− without detriment to the category to EN ISO 13849-1 | |
Active principle | inductive |
Duty cycle | 100 % |
Materials | |
– Material of the housings | Plastic, glass-fibre reinforced thermoplastic |
Housing coating | None |
Weight | 500 g |
Guard locking monitored (Y/N) | No |
Actuator monitored (Y/N) | Yes |
Idle assignable pushbutton and LED (Y/N) | No |
Reaction time | < 150 ms |
Duration of risk | < 150 ms |
Time to readiness | < 4000 ms |
Recommended actuator | MZM 100-B1.1 |
Mechanical data | |
Design of electrical connection | Connector M12, 8-pole |
Mechanical life | ≥ 1.000.000 operations |
notice – Mechanical life | operations for guards ≤ 5 kg; actuating speed ≤ 0,5 m/s |
restistance to shock | 30 g / 11 ms |
Resistance to vibration | 10 … 150 Hz, Amplitude 0,35 mm |
Emergency unlocking device (Y/N) | No |
Manual release (Y/N) | No |
Emergency release (Y/N) | No |
Latching (Y/N) | Yes |
electrically adjustable latching force | 30 N … 100 N |
Permanent magnet | – |
Clamping force F | |
– typically | 750 N |
– guaranteed | 500 N |
Ambient conditions | |
Ambient temperature | |
– Min. environmental temperature | −25 °C |
– Max. environmental temperature | +55 °C |
Storage and transport temperature | |
– Min. Storage and transport temperature | −25 °C |
– Max. Storage and transport temperature | +85 °C |
Relative humidity | 30% … 95% |
– non-condensing | |
– non-icing | |
Protection class | IP67 to IEC/EN 60529 |
Air clearances and creepage distances To IEC/EN 60664-1 | |
– Rated impulse withstand voltage Uimp | 0,8 kV |
– Overvoltage category | III |
– Degree of pollution | 3 |
Electrical data | |
Number of auxiliary contacts | 0 piece |
Number of safety contacts | 2 piece |
Cross circuit/short circuit recognition possible (Y/N) | Yes |
Power to unlock | No |
Power to lock | Yes |
Supply voltage UB (stabilised PELV) | |
– Min. supply voltage | 20.4 VDC |
– Max. supply voltage | 26.4 VDC |
Switch frequency | 1 Hz |
Rated insulation voltage Ui | 32 VDC |
Operating current Ie | 1 A |
Utilisation category | DC-13 |
No-load current I0 | max. 0,5 A |
Required rated short-circuit current | 100 A |
Device insulation | ≤ 2 A (if used in accordance with UL 508) |
notice | Cable length and cable section alter the voltage drop depending on the output current |
Electrical data – Safety inputs | |
Safety inputs | X1 and X2 |
Rated operating voltage Ue | −3 V … 5 V (Low) 15 V … 30 V (High) |
Operating current Ie | > 2 mA / 24 V |
Electrical data – Safety outputs | |
Safety outputs | Y1 and Y2 |
Fuse rating | short-circuit proof, p-type |
Rated operating voltage | 0 V … 4 V under Supply voltage UB |
Residual current Ir | ≤ 0,5 mA |
Operating current Ie | 0,25 A |
Utilisation category | DC-12, DC-13 |
Electrical data – Diagnostic output | |
Serial diagnostics (Y/N) | No |
Fuse rating | p-type, short-circuit proof |
Rated operating voltage | −3 V … 5 V (Low) 15 V … 30 V (High) |
Operating current Ie | 0,05 A |
Utilisation category | DC-12, DC-13 |
Wiring capacitance for serial diagnostics | – |
diagnostic signals | guard door closed and interlocking device locked |
Operating principle of the diagnostic output | The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC. |
notice | The diagnostic output is not a safety-relevant output! |
Electrical data – Solenoid control IN | |
Rated operating voltage Ue | −3 V … 5 V (Low) 15 V … 30 V (High) |
Operating current Ie | typically 10 mA / 24 V, dynamically 20 mA |
LED switching conditions display | |
LED switching conditions display (Y/N) | Yes |
LED switching conditions display | |
– Supply voltage UB | green LED |
– switching condition | yellow LED |
– Error functional defect | red LED |
ATEX | |
Explosion protection categories for gases | None |
Explosion protected category for dusts | None |
Dimensions | |
Dimensions of the sensor | |
– Width of sensor | 40 mm |
– Height of sensor | 179 mm |
– Length of sensor | 40 mm |
Pin assignment | |
1 | A1 Supply voltage UB |
2 | X1 Safety input 1 |
3 | A2 GND |
4 | Y1 Safety output 1 |
5 | OUT Diagnostic output |
6 | X2 Safety input 2 |
7 | Y2 Safety output 2 |
8 | IN Solenoid control |