Schmersal MZM 100B ST2-1P2PW2RE-A-2781-1

Schmersal MZM 100B ST2-1P2PW2RE-A-2781-1

Thông số kỹ thuật MZM 100B ST2-1P2PW2RE-A-2781-1

MZM 100 B ST-1P2PW2REM-A
MZM 100 B ST2-1P2PW2RE-A
MZM 100 B ST2-1P2PW2REM-A
MZM 100 B ST2-SD2PRE-A
MZM 100 B ST2-SD2PREM-A
MZM 100 ST-1P2PW-A
MZM 100 ST-1P2PWM-A
MZM 100 ST-1P2PWRE-A
MZM 100 ST-1P2PWREM-A
MZM 100 ST-SD2P-A
MZM 100 ST-SD2PRE-A
MZM 100 ST-SD2PREM-A
MZM 100 ST2-1P2PW-A
MZM 100 ST2-1P2PWM-A
MZM 100 ST2-1P2PWRE-A
MZM 100 ST2-1P2PWREM-A
MZM 100 ST2-SD2P-A
MZM 100 ST2-SD2PRE-A
MZM 100 ST2-SD2PREM-A

đại lý MZM 100B ST2-1P2PW2RE-A-2781-1 | nhà phân phối MZM 100B ST2-1P2PW2RE-A-2781-1

Ordering details
Product type description MZM 100 B ST2-1P2PW2RE-A
Article number 101211070
EAN code 4030661389080
eCl@ss 27-27-26-03
Approval
Approval BG
USA/CAN
Classification
Standards EN ISO 13849-1, IEC 61508, IEC 60947-5-3, EN 60947-5-1
PL e
Control category up 4
PFH 3.5 x 10-9/h
SIL up 3
Mission time 20 Years
Classification PDF-M
Global Properties
Product name MZM 100
Standards IEC 61508, EN ISO 13849-1, EN ISO 13849-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N) Yes
Protection rating II
Series-wiring up to 31 components
Length of the sensor chain max. 200 m
− without detriment to the category to EN ISO 13849-1
Active principle inductive
Duty cycle 100 %
Materials
– Material of the housings Plastic, glass-fibre reinforced thermoplastic
Housing coating None
Weight 500 g
Guard locking monitored (Y/N) No
Actuator monitored (Y/N) Yes
Idle assignable pushbutton and LED (Y/N) No
Reaction time < 150 ms
Duration of risk < 150 ms
Time to readiness < 4000 ms
Recommended actuator MZM 100-B1.1
Mechanical data
Design of electrical connection Connector M12, 8-pole
Mechanical life ≥ 1.000.000 operations
notice – Mechanical life operations for guards ≤ 5 kg;
actuating speed ≤ 0,5 m/s
restistance to shock 30 g / 11 ms
Resistance to vibration 10 … 150 Hz, Amplitude 0,35 mm
Emergency unlocking device (Y/N) No
Manual release (Y/N) No
Emergency release (Y/N) No
Latching (Y/N) Yes
electrically adjustable latching force 30 N … 100 N
Permanent magnet
Clamping force F
– typically 750 N
– guaranteed 500 N
Ambient conditions
Ambient temperature
– Min. environmental temperature −25 °C
– Max. environmental temperature +55 °C
Storage and transport temperature
– Min. Storage and transport temperature −25 °C
– Max. Storage and transport temperature +85 °C
Relative humidity 30% … 95%
– non-condensing
– non-icing
Protection class IP67 to IEC/EN 60529
Air clearances and creepage distances To IEC/EN 60664-1
– Rated impulse withstand voltage Uimp 0,8 kV
– Overvoltage category III
– Degree of pollution 3
Electrical data
Number of auxiliary contacts 0 piece
Number of safety contacts 2 piece
Cross circuit/short circuit recognition possible (Y/N) Yes
Power to unlock No
Power to lock Yes
Supply voltage UB (stabilised PELV)
– Min. supply voltage 20.4 VDC
– Max. supply voltage 26.4 VDC
Switch frequency 1 Hz
Rated insulation voltage Ui 32 VDC
Operating current Ie 1 A
Utilisation category DC-13
No-load current I0 max. 0,5 A
Required rated short-circuit current 100 A
Device insulation ≤ 2 A (if used in accordance with UL 508)
notice Cable length and cable section alter the voltage drop depending on the output current
Electrical data – Safety inputs
Safety inputs X1 and X2
Rated operating voltage Ue −3 V … 5 V (Low)
15 V … 30 V (High)
Operating current Ie > 2 mA / 24 V
Electrical data – Safety outputs
Safety outputs Y1 and Y2
Fuse rating short-circuit proof, p-type
Rated operating voltage 0 V … 4 V under Supply voltage UB
Residual current Ir ≤ 0,5 mA
Operating current Ie 0,25 A
Utilisation category DC-12, DC-13
Electrical data – Diagnostic output
Serial diagnostics (Y/N) No
Fuse rating p-type, short-circuit proof
Rated operating voltage −3 V … 5 V (Low)
15 V … 30 V (High)
Operating current Ie 0,05 A
Utilisation category DC-12, DC-13
Wiring capacitance for serial diagnostics
diagnostic signals guard door closed and interlocking device locked
Operating principle of the diagnostic output The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC.
notice The diagnostic output is not a safety-relevant output!
Electrical data – Solenoid control IN
Rated operating voltage Ue −3 V … 5 V (Low)
15 V … 30 V (High)
Operating current Ie typically 10 mA / 24 V, dynamically 20 mA
LED switching conditions display
LED switching conditions display (Y/N) Yes
LED switching conditions display
– Supply voltage UB green LED
– switching condition yellow LED
– Error functional defect red LED
ATEX
Explosion protection categories for gases None
Explosion protected category for dusts None
Dimensions
Dimensions of the sensor
– Width of sensor 40 mm
– Height of sensor 179 mm
– Length of sensor 40 mm
Pin assignment
1 A1 Supply voltage UB
2 X1 Safety input 1
3 A2 GND
4 Y1 Safety output 1
5 OUT Diagnostic output
6 X2 Safety input 2
7 Y2 Safety output 2
8 IN Solenoid control