Schmersal MZM 100B ST2-1P2PW2RE-A-2781-1
Thông số kỹ thuật MZM 100B ST2-1P2PW2RE-A-2781-1
MZM 100 B ST-1P2PW2REM-A
MZM 100 B ST2-1P2PW2RE-A
MZM 100 B ST2-1P2PW2REM-A
MZM 100 B ST2-SD2PRE-A
MZM 100 B ST2-SD2PREM-A
MZM 100 ST-1P2PW-A
MZM 100 ST-1P2PWM-A
MZM 100 ST-1P2PWRE-A
MZM 100 ST-1P2PWREM-A
MZM 100 ST-SD2P-A
MZM 100 ST-SD2PRE-A
MZM 100 ST-SD2PREM-A
MZM 100 ST2-1P2PW-A
MZM 100 ST2-1P2PWM-A
MZM 100 ST2-1P2PWRE-A
MZM 100 ST2-1P2PWREM-A
MZM 100 ST2-SD2P-A
MZM 100 ST2-SD2PRE-A
MZM 100 ST2-SD2PREM-A
đại lý MZM 100B ST2-1P2PW2RE-A-2781-1 | nhà phân phối MZM 100B ST2-1P2PW2RE-A-2781-1
| Ordering details | |
| Product type description | MZM 100 B ST2-1P2PW2RE-A |
| Article number | 101211070 |
| EAN code | 4030661389080 |
| eCl@ss | 27-27-26-03 |
| Approval | |
| Approval | BG USA/CAN |
| Classification | |
| Standards | EN ISO 13849-1, IEC 61508, IEC 60947-5-3, EN 60947-5-1 |
| PL | e |
| Control category | up 4 |
| PFH | 3.5 x 10-9/h |
| SIL | up 3 |
| Mission time | 20 Years |
| Classification | PDF-M |
| Global Properties | |
| Product name | MZM 100 |
| Standards | IEC 61508, EN ISO 13849-1, EN ISO 13849-1 |
Compliance with the Directives (Y/N) ![]() |
Yes |
| Suitable for safety functions (Y/N) | Yes |
| Protection rating | II |
| Series-wiring | up to 31 components |
| Length of the sensor chain | max. 200 m |
| − without detriment to the category to EN ISO 13849-1 | |
| Active principle | inductive |
| Duty cycle | 100 % |
| Materials | |
| – Material of the housings | Plastic, glass-fibre reinforced thermoplastic |
| Housing coating | None |
| Weight | 500 g |
| Guard locking monitored (Y/N) | No |
| Actuator monitored (Y/N) | Yes |
| Idle assignable pushbutton and LED (Y/N) | No |
| Reaction time | < 150 ms |
| Duration of risk | < 150 ms |
| Time to readiness | < 4000 ms |
| Recommended actuator | MZM 100-B1.1 |
| Mechanical data | |
| Design of electrical connection | Connector M12, 8-pole |
| Mechanical life | ≥ 1.000.000 operations |
| notice – Mechanical life | operations for guards ≤ 5 kg; actuating speed ≤ 0,5 m/s |
| restistance to shock | 30 g / 11 ms |
| Resistance to vibration | 10 … 150 Hz, Amplitude 0,35 mm |
| Emergency unlocking device (Y/N) | No |
| Manual release (Y/N) | No |
| Emergency release (Y/N) | No |
| Latching (Y/N) | Yes |
| electrically adjustable latching force | 30 N … 100 N |
| Permanent magnet | – |
| Clamping force F | |
| – typically | 750 N |
| – guaranteed | 500 N |
| Ambient conditions | |
| Ambient temperature | |
| – Min. environmental temperature | −25 °C |
| – Max. environmental temperature | +55 °C |
| Storage and transport temperature | |
| – Min. Storage and transport temperature | −25 °C |
| – Max. Storage and transport temperature | +85 °C |
| Relative humidity | 30% … 95% |
| – non-condensing | |
| – non-icing | |
| Protection class | IP67 to IEC/EN 60529 |
| Air clearances and creepage distances To IEC/EN 60664-1 | |
| – Rated impulse withstand voltage Uimp | 0,8 kV |
| – Overvoltage category | III |
| – Degree of pollution | 3 |
| Electrical data | |
| Number of auxiliary contacts | 0 piece |
| Number of safety contacts | 2 piece |
| Cross circuit/short circuit recognition possible (Y/N) | Yes |
| Power to unlock | No |
| Power to lock | Yes |
| Supply voltage UB (stabilised PELV) | |
| – Min. supply voltage | 20.4 VDC |
| – Max. supply voltage | 26.4 VDC |
| Switch frequency | 1 Hz |
| Rated insulation voltage Ui | 32 VDC |
| Operating current Ie | 1 A |
| Utilisation category | DC-13 |
| No-load current I0 | max. 0,5 A |
| Required rated short-circuit current | 100 A |
| Device insulation | ≤ 2 A (if used in accordance with UL 508) |
| notice | Cable length and cable section alter the voltage drop depending on the output current |
| Electrical data – Safety inputs | |
| Safety inputs | X1 and X2 |
| Rated operating voltage Ue | −3 V … 5 V (Low) 15 V … 30 V (High) |
| Operating current Ie | > 2 mA / 24 V |
| Electrical data – Safety outputs | |
| Safety outputs | Y1 and Y2 |
| Fuse rating | short-circuit proof, p-type |
| Rated operating voltage | 0 V … 4 V under Supply voltage UB |
| Residual current Ir | ≤ 0,5 mA |
| Operating current Ie | 0,25 A |
| Utilisation category | DC-12, DC-13 |
| Electrical data – Diagnostic output | |
| Serial diagnostics (Y/N) | No |
| Fuse rating | p-type, short-circuit proof |
| Rated operating voltage | −3 V … 5 V (Low) 15 V … 30 V (High) |
| Operating current Ie | 0,05 A |
| Utilisation category | DC-12, DC-13 |
| Wiring capacitance for serial diagnostics | – |
| diagnostic signals | guard door closed and interlocking device locked |
| Operating principle of the diagnostic output | The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC. |
| notice | The diagnostic output is not a safety-relevant output! |
| Electrical data – Solenoid control IN | |
| Rated operating voltage Ue | −3 V … 5 V (Low) 15 V … 30 V (High) |
| Operating current Ie | typically 10 mA / 24 V, dynamically 20 mA |
| LED switching conditions display | |
| LED switching conditions display (Y/N) | Yes |
| LED switching conditions display | |
| – Supply voltage UB | green LED |
| – switching condition | yellow LED |
| – Error functional defect | red LED |
| ATEX | |
| Explosion protection categories for gases | None |
| Explosion protected category for dusts | None |
| Dimensions | |
| Dimensions of the sensor | |
| – Width of sensor | 40 mm |
| – Height of sensor | 179 mm |
| – Length of sensor | 40 mm |
| Pin assignment | |
| 1 | A1 Supply voltage UB |
| 2 | X1 Safety input 1 |
| 3 | A2 GND |
| 4 | Y1 Safety output 1 |
| 5 | OUT Diagnostic output |
| 6 | X2 Safety input 2 |
| 7 | Y2 Safety output 2 |
| 8 | IN Solenoid control |

BG
USA/CAN