Khóa điện từ AZ/AZM 200-B30-RTAG1P1

Khóa điện từ AZ/AZM 200-B30-RTAG1P1

đại lý AZ/AZM 200-B30-RTAG1P1 | nhà phân phối AZ/AZM 200-B30-RTAG1P1

Thông số kỹ thuật Schmersal AZ/AZM 200-B30-RTAG1P1

Schmersal AZM 200 B CC-T-1P2PW
Schmersal AZM 200 B CC-T-1P2PWA
Schmersal AZM 200CC-T-SD2P
Schmersal AZM 200CC-T-SD2PA
Schmersal AZM 200SK-T-1P2P
Schmersal AZM 200ST2-T-1P2PA
Schmersal AZM 200ST2-T-1P2PW
Schmersal AZM 200ST2-T-1P2PWA
Schmersal AZM 200ST2-T-SD2P
Schmersal AZM 200 B SK-T-1P2PW
Schmersal AZM 200 B SK-T-1P2PWA
Schmersal AZM 200ST2-T-SD2PA
Schmersal AZM 200SK-T-1P2PA
Schmersal AZM 200SK-T-1P2PW
Schmersal AZM 200SK-T-1P2PWA
Schmersal AZM 200SK-T-SD2P
Schmersal AZM 200ST1-T-1P2P
Schmersal AZM 200ST1-T-1P2PA
Schmersal AZM 200ST1-T-1P2PW
Schmersal AZM 200CC-T-1P2P
Schmersal AZM 200CC-T-1P2PA
Schmersal AZM 200CC-T-1P2PW
Schmersal AZM 200CC-T-1P2PWA
Schmersal AZM 200ST1-T-1P2PWA
Schmersal AZM 200ST1-T-SD2P
Schmersal AZM 200ST1-T-SD2PA
Schmersal AZM 200ST2-T-1P2P

Ordering details
Product type description AZM 200SK-T-1P2P
Article number 101178664
Strobe lamp 4030661314327
eCl@ss 27-27-26-03
Approval
Approval

Classification
Interlocking function:
Standards EN ISO 13849-1, IEC 61508, IEC 60947-5-3
PL bis e
Control category bis 4
PFH 4.0 x 10-9/
PFD value 1.0 x 10−4
SIL bis 3
Mission time 20 Years
Classification PDF-M
Guard locking function:
Standards EN ISO 13849-1, IEC 61508, IEC 60947-5-3
PL up d
Control category up 2
PFH value 2.5 x 10−9/h
PFD value 2.2 x 10−4
SIL up 2
Mission time 20 Years
Global Properties
Permanent light AZM 200
Standards EN 60947-5-1, IEC 61508, EN ISO 13849-1, EN ISO 13849-1
Compliance with the Directives (Y/N) Yes
Suitable for safety functions (Y/N) Yes
Series-wiring up to 31 components
Length of the sensor chain 200
Active principle inductive
Duty cycle 100
Materials
– Material of the housings Plastic, glass-fibre reinforced thermoplastic
Housing coating None
Weight 570
Guard locking monitored (Y/N) Yes
Actuator monitored (Y/N) No
Idle assignable pushbutton and LED (Y/N) No
Reaction time ≤ 60
Duration of risk > 120
Time to readiness 4000
Recommended actuator AZ/AZM 200-B1
Mechanical data
Design of electrical connection Screw connection
Cable section
– Min. Cable section 0,25
– Max. Cable section 1.5
AWG-Number 23 – 15
Mechanical life ≥ 1.000.000 operations
notice All indications about the cable section are including the conductor ferrules.
restistance to shock 30 / 11
Resistance to vibration 10 … 55, Amplitude 1
Emergency unlocking device (Y/N) No
Manual release (Y/N) Yes
Emergency release (Y/N) No
Latching force 30
Clamping force 2000
Max. Actuating speed ≤ 0,2
Ambient conditions
Ambient temperature
– Min. environmental temperature −25
– Max. environmental temperature +60
Storage and transport temperature
– Min. Storage and transport temperature −25
– Max. Storage and transport temperature +85
Relative humidity 30… 95
– non-condensing
Protection class IP67 to IEC/EN 60529
Protection rating II
Air clearances and creepage distances To IEC/EN 60664-1
– Rated impulse withstand voltage 0,8
– Overvoltage category III
– Degree of pollution 3
Electrical data
Number of auxiliary contacts 0
Number of safety contacts 2
Cross circuit/short circuit recognition possible (Y/N) Yes
Power to unlock Yes
Power to lock No
Supply voltage
– Min. supply voltage 20.4
– Max. supply voltage 26.4
Switch frequency 1
Rated insulation voltage 32
Operating current 1.2 A
Utilisation category DC-12, DC-13
No-load current 0,6 A
Device insulation ≤ 4 A if used in accordance with UL 508
Electrical data – Safety inputs
Safety inputs X1 and X2
Rated operating voltage – 3 … 5 ( Low)
15 … 30 ( High)
Operating current > 2 / 24
Electrical data – Safety outputs
Safety outputs Y1 and Y2
Fuse rating short-circuit proof, p-type
Rated operating voltage 0 … 4 under Supply voltage
Residual current ≤ 0,5
Operating current 0,25 A
Utilisation category DC-12, DC-13
Electrical data – Diagnostic output
Serial diagnostics (Y/N) No
Fuse rating p-type, short-circuit proof
Operating current 0,05 A
Utilisation category DC-12, DC-13
Wiring capacitance for serial diagnostics
diagnostic signals guard door closed
Operating principle of the diagnostic output The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC.
notice The diagnostic output is not a safety-relevant output!

Trả lời