Cảm biến IFL 4B-12-10STPK1
Thông số kỹ thuật cảm biến Schmersal IFL 4B-12-10STPK1
đại lý schmersal | đại lý IFL 4B-12-10STPK1
nhà phân phối schmersal | nhà phân phối IFL 4B-12-10STPK1
- Metal enclosure
- DC 3-wire
- Connector M12
- higher switching distance
- Design M12
Ordering data
| Product type description |
IFL 4B-12-10STPK1 |
| Article number (order number) |
101106015 |
| EAN (European Article Number) |
4030661048482 |
| eCl@ss number, version 12.0 |
27-27-40-01 |
| eCl@ss number, version 11.0 |
27-27-01-01 |
| eCl@ss number, version 9.0 |
27-27-01-01 |
| ETIM number, version 7.0 |
EC002714 |
| ETIM number, version 6.0 |
EC002714 |
Approvals – Standards
| Certificates |
CCC |
General data
| Standards |
DIN VDE 0660-208 EN IEC 60947-5-2 |
| Housing construction form |
Cylinder, thread |
| Installation conditions (mechanical) |
Quasi-embeddable |
| Note (Installation condition) |
Steel: x ≥ 2.4 mm Other metal: x ≥ 1.2 mm |
| Housing material |
Brass |
| Housing coating material |
nickel-plated |
| Active area |
Plastic |
| Material of the nuts |
Nickel plated brass |
| Gross weight |
34 g |
General data – Features
| Integral system diagnostics, status |
Yes |
| Number of cable wires |
3 |
Mechanical data
| Tightening torque of nuts, maximum |
15 Nm |
| Note (Tightening torque of nuts) |
In the shell core area: max. 500 Ncm |
Mechanical data – Switching distances according EN IEC 60947-5-3
| Nominal switching distance Sn |
4 mm |
Mechanical data – Connection technique
| Termination |
Connector M12 |
Mechanical data – Dimensions
| ISO thread of the sensor |
M12 |
| width across flats |
17 BK |
| Length of sensor |
61 mm |
Ambient conditions
| Degree of protection |
IP67 |
| Ambient temperature |
-25 … +70 °C |
| Protection class |
0 |
Electrical data
| No-load supply current I0, typical |
0.5 mA |
| Rated operating voltage |
5 … 40 VDC |
| Operating current |
200 mA |
| Switching element |
Normally open contact (NO) |
| Protection circuit integrated |
inductive interference protection Protection against polarity reversal Surge protection short-circuit protection (pulsed) |
| Switching frequency, approx. |
600 Hz |
| VOLT_TYPE_RANGE |
DC |
Electrical data – Digital Output
| Voltage drop Ud, maximum |
1.3 V |
| Current at Voltage drop Ud |
0.2 A |
| Design of control elements |
p-type |
Status indication
| Note (Integral System Diagnostics, status ) |
yellow LED |
Note
| Note (General) |
Instead of nuts, a mounting clamp can be provided. |