Khóa điện từ AZM 200SK-T-1P2P
đại lý AZM 200SK-T-1P2P | schmersal AZM 200SK-T-1P2P | nhà phân phối AZM 200SK-T-1P2P
Thông số kỹ thuật Schmersal AZM200SK-T-1P2P
| Ordering details | |
| Product type description | AZM 200SK-T-1P2P |
| Article number | 101178664 |
| Strobe lamp | 4030661314327 |
| eCl@ss | 27-27-26-03 |
| Approval | |
| Approval | ![]() ![]() ![]() |
| Classification | |
| Interlocking function: | |
| Standards | EN ISO 13849-1, IEC 61508, IEC 60947-5-3 |
| PL | bis e |
| Control category | bis 4 |
| PFH | 4.0 x 10-9/ |
| PFD value | 1.0 x 10−4 |
| SIL | bis 3 |
| Mission time | 20 Years |
| Classification | PDF-M |
| Guard locking function: | |
| Standards | EN ISO 13849-1, IEC 61508, IEC 60947-5-3 |
| PL | up d |
| Control category | up 2 |
| PFH value | 2.5 x 10−9/h |
| PFD value | 2.2 x 10−4 |
| SIL | up 2 |
| Mission time | 20 Years |
| Global Properties | |
| Permanent light | AZM 200 |
| Standards | EN 60947-5-1, IEC 61508, EN ISO 13849-1, EN ISO 13849-1 |
Compliance with the Directives (Y/N) ![]() |
Yes |
| Suitable for safety functions (Y/N) | Yes |
| Series-wiring | up to 31 components |
| Length of the sensor chain | 200 |
| Active principle | inductive |
| Duty cycle | 100 |
| Materials | |
| – Material of the housings | Plastic, glass-fibre reinforced thermoplastic |
| Housing coating | None |
| Weight | 570 |
| Guard locking monitored (Y/N) | Yes |
| Actuator monitored (Y/N) | No |
| Idle assignable pushbutton and LED (Y/N) | No |
| Reaction time | ≤ 60 |
| Duration of risk | > 120 |
| Time to readiness | 4000 |
| Recommended actuator | AZ/AZM 200-B1 |
| Mechanical data | |
| Design of electrical connection | Screw connection |
| Cable section | |
| – Min. Cable section | 0,25 |
| – Max. Cable section | 1.5 |
| AWG-Number | 23 – 15 |
| Mechanical life | ≥ 1.000.000 operations |
| notice | All indications about the cable section are including the conductor ferrules. |
| restistance to shock | 30 / 11 |
| Resistance to vibration | 10 … 55, Amplitude 1 |
| Emergency unlocking device (Y/N) | No |
| Manual release (Y/N) | Yes |
| Emergency release (Y/N) | No |
| Latching force | 30 |
| Clamping force | 2000 |
| Max. Actuating speed | ≤ 0,2 |
| Ambient conditions | |
| Ambient temperature | |
| – Min. environmental temperature | −25 |
| – Max. environmental temperature | +60 |
| Storage and transport temperature | |
| – Min. Storage and transport temperature | −25 |
| – Max. Storage and transport temperature | +85 |
| Relative humidity | 30… 95 |
| – non-condensing | |
| Protection class | IP67 to IEC/EN 60529 |
| Protection rating | II |
| Air clearances and creepage distances To IEC/EN 60664-1 | |
| – Rated impulse withstand voltage | 0,8 |
| – Overvoltage category | III |
| – Degree of pollution | 3 |
| Electrical data | |
| Number of auxiliary contacts | 0 |
| Number of safety contacts | 2 |
| Cross circuit/short circuit recognition possible (Y/N) | Yes |
| Power to unlock | Yes |
| Power to lock | No |
| Supply voltage | |
| – Min. supply voltage | 20.4 |
| – Max. supply voltage | 26.4 |
| Switch frequency | 1 |
| Rated insulation voltage | 32 |
| Operating current | 1.2 A |
| Utilisation category | DC-12, DC-13 |
| No-load current | 0,6 A |
| Device insulation | ≤ 4 A if used in accordance with UL 508 |
| Electrical data – Safety inputs | |
| Safety inputs | X1 and X2 |
| Rated operating voltage | – 3 … 5 ( Low) 15 … 30 ( High) |
| Operating current | > 2 / 24 |
| Electrical data – Safety outputs | |
| Safety outputs | Y1 and Y2 |
| Fuse rating | short-circuit proof, p-type |
| Rated operating voltage | 0 … 4 under Supply voltage |
| Residual current | ≤ 0,5 |
| Operating current | 0,25 A |
| Utilisation category | DC-12, DC-13 |
| Electrical data – Diagnostic output | |
| Serial diagnostics (Y/N) | No |
| Fuse rating | p-type, short-circuit proof |
| Operating current | 0,05 A |
| Utilisation category | DC-12, DC-13 |
| Wiring capacitance for serial diagnostics | – |
| diagnostic signals | guard door closed |
| Operating principle of the diagnostic output | The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC. |
| notice | The diagnostic output is not a safety-relevant output! |
| Electrical data – Solenoid control IN | |
| Rated operating voltage | – 3 … 5 ( Low) 15 … 30 ( High) |
| Operating current | typically 10 / 24 , dynamically 20 |
| LED switching conditions display | |
| LED switching conditions display (Y/N) | Yes |
| LED switching conditions display | |
| – Supply voltage | green LED |
| – switching condition | yellow LED |
| – Error functional defect | red LED |
Schmersal AZM 200 B CC-T-1P2PW
Schmersal AZM 200 B CC-T-1P2PWA
Schmersal AZM 200 B SK-T-1P2PW
Schmersal AZM 200 B SK-T-1P2PWA
Schmersal AZM 200CC-T-1P2P
Schmersal AZM 200CC-T-1P2PA
Schmersal AZM 200CC-T-1P2PW
Schmersal AZM 200CC-T-1P2PWA
Schmersal AZM 200CC-T-SD2P
Schmersal AZM 200CC-T-SD2PA
Schmersal AZM 200SK-T-1P2P
Schmersal AZM 200SK-T-1P2PA
Schmersal AZM 200SK-T-1P2PW
Schmersal AZM 200SK-T-1P2PWA
Schmersal AZM 200SK-T-SD2P
Schmersal AZM 200ST1-T-1P2P
Schmersal AZM 200ST1-T-1P2PA
Schmersal AZM 200ST1-T-1P2PW
Schmersal AZM 200ST1-T-1P2PWA
Schmersal AZM 200ST1-T-SD2P
Schmersal AZM 200ST1-T-SD2PA
Schmersal AZM 200ST2-T-1P2P
Schmersal AZM 200ST2-T-1P2PA
Schmersal AZM 200ST2-T-1P2PW
Schmersal AZM 200ST2-T-1P2PWA
Schmersal AZM 200ST2-T-SD2P
Schmersal AZM 200ST2-T-SD2PA
Schmersal MS- AZM 200ST-T-1P2PWA-2568
Schmersal MS-AZM 200ST-T-1P2PW-2568
đại lý AZM 200CC-T-1P2P | nhà phân phối AZM 200ST1-T-SD2PA





Xin chào
Bên mình cần báo giá bộ khóa điện từ AZM200SK-T-1P2P, 24VDC
Vui long báo giá